Two channel time & attendance and access controller using iButtons, RF tags or magnetic cards.
Features
- alphanumeric LCD 24×2 with backlighting
- 2 configurable reader inputs (iButton, RF, PIN keyboards etc.)
- 2 voltage-free sensor inputs
- 2 voltage-free egress inputs
- 2 configurable relay outputs (12V or voltage-free, both polarities)
- outputs are galvanically isolated from MCU in all 4 configurations
- configurable relay-on time for all 2 relays
- time & attendance function (buffer for 8192 clockings)
- access control function (ID table of 4096, time and input state discrimination possible)
- PLC-type configuration (all events can affect all outputs)
- random event generation for all readers with settable probability (e.g. spot searches for exits, breath tests for entries)
- 8 time-events for signal generation on relay outputs (e.g. start/end of shift and coffee break signalling)
- Forced Entry alarms (door opened, corresponding relay inactive)
- Door Open Too Long alarm (time limit settable)
- AUX channel for attaching up to 8 additional AUX devices (readers, terminals, large clock displays etc.)
- PC communication over active 4-wire current loop (to 1000m)
- RJ-45 connector for direct connection to Ethernet – TCP/IP
- 12V/7Ah lead battery for up to 24h autonomy
- battery charger with up to 2,5A
- battery deep-discharge protection
- alarm output for indicating no-AC input voltage condition
- most connectors available both as RJ-11 and detachable screw terminals (5mm pitch)
Images
Connected products
Readers
|
ID media
|
AUX devices
|
Programs
|
Technical details
Input voltage |
220VAC with grounding |
Battery |
sealed lead-acid 12V/7Ah |
Autonomy |
3 to 24h (depending on the number and type of connected readers, terminals and actuators (locks, magnets etc.) |
Power |
50W, 75W, 100W depending on installed AC/DC converter |
Backup of data |
min. 30 days |
Buffer capacity |
8192 clockings |
Communication |
- Active current loop, 4 wires, 9600 Bd
- ETHERNET TCP/IP
|
Ambient temperature |
0 0C – 40 0C |
Mounting |
Internal |
Dimenzije kutije |
|
Requirements
- PC with Windows OS and free COM port (or connection via LAN or USB/COM interface);
- one or more SL-83 controllers;
- TK readers for iButtons or RF tags;
- AUX readers for iButtons or RF tags;
- RF cards, RF tags or iButtons (DS1990A);
- controller configuration SW – CommService;
- access control rights editing and upload SW – KatzeReports;
- clocking data download SW – CommService;
- time & attendance calendar entry and report generation SW -KatzeReports.